Back
to the
State-by-State
Regulated Medical Waste Resource Locator
|
Ohio
Infectious
Waste
Definition
of Infectious Waste
Managing Infectious Waste
Occupational
Safety and Health (OSHA)
Statutes, Regulations & Guidelines
Contact
More
Information
Definition of Infectious
Waste
"Infectious wastes" includes
all of the following substances or categories of
substances:
- Cultures and stocks of infectious agents and associated
biologicals.
- Laboratory wastes that were, or are likely to have
been, in contact with infectious agents.
- Pathological wastes, including human and animal tissues,
organs, and body parts, and body fluids and excreta that are contaminated
with or are likely to be contaminated with infectious agents.
- Waste materials from the rooms of humans, or the enclosures
of animals, that have been isolated because of diagnosed communicable
disease that are likely to transmit infectious agents.
- Human and animal blood specimens and blood products
that are being disposed of.
- Contaminated carcasses, body parts, and bedding of
animals that were intentionally exposed to infectious agents.
- Sharp wastes used in the treatment, diagnosis, or inoculation
of human beings or animals
- Any other waste materials generated in the diagnosis,
treatment, or immunization of human beings or animals, in research
or in the production of testing of biologicals.
- Any other waste materials the generator designates
as infectious waste.
Regulation of Infectious Wastes
The Ohio EPA's Infectious Waste Program regulates
the generation, treatment, packaging, storage, transportation, and
disposal of infectious waste in the state. The detailed requirements
can be found in Ohio
Revised Code Chapter (ORC) 3734. Ohio
Administrative Code Chapters (OAC) 3745-27
and 3745-37. Depending upon the amount of infectious waste generated
in a calendar month a person is considered to be a small generator
(less than 50 lbs per month) or a large generator (50 lbs or more a
calendar month). A large generator must submit a registration application
to the Ohio EPA.
Managing Infectious Waste
Veterinary facilities
are divided into two categories, depending on the quantity of infectious
waste that they generate:
- small quantity generators
(less than 50 pounds per month of infectious waste), and
- large quantity generators
(50 or more pounds of infectious waste in any one month).
When
calculating the quantity of infectious waste generated, do not consider
the weight of blood, blood products, other body fluids, or embalming
fluids that are legally discharged to a sewer system.
Rules
for these two categories are provided below.
Large Quantity
Generators
Generator Registration.
A healthcare facility or other generator of infectious waste who generates
50 pounds or more of infectious waste during any one month must register
with the Ohio EPA. Once a facility is registered, they are given a
registration certificate and they must follow certain rules covering
management and disposal of infectious waste.
For details concerning
the registration process, see Requirements for Infectious Waste Registration
Certificate, below.
Procedures. Large
quantity generators must implement the following procedures:
- Place all "sharps" in
a suitable container (rigid, puncture-resistant, leak resistant,
and closed tightly to prevent loss of contents).
- Either treat all specimen
cultures and cultures of viable infectious agents on the premises
where they are generated to render them noninfectious or ensure
that the wastes are treated to render them noninfectious at a treatment
facility.
- Quantify the waste generation
rate and keep records recorded in pounds on a calendar month basis. This
rule can be met by keeping a monthly generation rate log, keeping
treatment shipping papers that document the weight of all the infectious
waste that is generated and sent for treatment documented in pounds
for a calendar month; or a combination of a monthly generation
rate log and treatment shipping papers.
- Not grind any sharp infectious
wastes, not compact any such wastes until after the wastes have
been treated.
- Dispose of the infectious
wastes at a solid waste disposal facility holding an appropriate
license.
- Employ only transporters
who are registered to transport untreated infectious wastes.
- Provide information to
transporters and treatment facilities regarding the generator's
system for distinguishing between waste packages that contain treated
and untreated wastes.
- Ensure that all infectious
wastes, whether treated or untreated, that are transported offsite
are accompanied by a shipping paper (see Infectious Waste Shipping
Paper System, below).
- Develop a spill containment
and clean-up procedure.
- Ensure that clean-up materials
/ kits are available in those areas designated in the spill containment
and clean-up procedures and that they are effectively utilized,
as needed.
- Generators of infectious
wastes may discharge untreated liquid or semi-liquid infectious
wastes consisting of blood, blood products, body fluids, and excreta
into a sewer system provided it is not otherwise regulated by the
local authority.
- A generator of infectious
wastes may transport off-site infectious wastes that have been
treated to render them noninfectious in the same manner as noninfectious
wastes are transported.
- A hospital may accept for
treatment or storage prior to transportation to a treatment facility
the following wastes:
- Properly packaged sharp
infectious wastes and all unused discarded hypodermic needles,
syringes, and scalpel blades that are generated by a small quantity
generator.
- Infectious wastes generated
by an individual for purposes of his/her own care or treatment.
- Infectious wastes generated
in providing care to a patient by an emergency medical services
organization.
Small Quantity
Generators
Although small quantity
generators are exempt from some of the regulations that pertain to
large quantity generators, such as use of the shipping paper system,
they still must meet certain basic rules:
- Identify and separate infectious
from non-infectious waste at the point of generation for the purposes
of determining the generator status (small vs. large) the facility.
- Quantify the waste generation
rate and keep records recorded in pounds on a calendar month basis. This
rule can be met by keeping a monthly generation rate log, keeping
treatment shipping papers that document the weight of all the infectious
waste that is generated and sent for treatment documented in pounds
for a calendar month; or a combination of a monthly generation
rate log and treatment shipping papers.
- Determine by monthly records
if fifty pounds or more of infectious waste is generated. If the
monthly quantity reaches 50 pounds in any month, the facility must
register and obtain a certificate.
- Place all "sharps" in
a suitable container (rigid, puncture-resistant, leak resistant,
and closed tightly to prevent loss of contents).
- Either treat all specimen
cultures and cultures of viable infectious agents on the premises
where they are generated to render them noninfectious or ensure
that the wastes are treated to render them noninfectious at a treatment
facility.
- A small quantity generator
who complies with the above sharps rules may transport and dispose
of infectious wastes in the same manner as solid wastes.
Packaging and
Labeling Infections Waste
The following rules apply
to packaging of infectious waste.
Bags
must be red in color or conspicuously labeled with the international
biohazard symbol.
- Each bag must be constructed
of material of sufficient single thickness to preclude ripping,
tearing, or bursting under normal conditions.
- Bags must be of sufficient
film strength, strength of seals, and leakage resistance.
- Bags must be impervious
to moisture;
- Filled bags must be securely
tied or sealed to prevent leakage or expulsion of wastes from them
during storage, handling, or transport.
- Bags containing infectious
wastes that are being transported off-site must be placed inside
a second sealed plastic bag or one single bag within a fully enclosed,
rigid, sturdy container.
- Containers for infectious
waste must be at a minimum labeled with the international biohazard
symbol on two opposite sides.
- Reusable containers must
be thoroughly cleaned with a detergent and disinfected after each
use.
- Sharps containers must
be rigid, puncture-resistant, leak resistant, and closed tightly
to prevent loss of contents. Sharps containers must be only those
containers specifically designed and manufactured for the management
and/or disposal of sharps.
Storage Requirements
The following rules apply
to the storage of infectious waste:
- Infectious waste must be
stored in a manner which maintains the integrity of the packaging.
- Infectious waste must be
kept in a nonputrescent state.
- Clearly mark all storage
areas.
- Infectious waste must be
stored in a manner such that the IW does not become a food source
or breeding place for insects or animals.
- Outside storage areas must
be locked.
- May not store IW for more
than 35 days.
- "In-use" sharps containers
are not considered storage.
On-Site Treatment
of Infectious Waste
Large generators that
treat infectious waste on-site must abide with certain rules. Treatment
methods approved in the state of Ohio include:
- Incineration,
- Autoclaving,
- Chemical treatment, and
- Encapsulation.
Alternative
treatment technologies must be approved by the Ohio EPA.
For details on infectious
waste treatment, see Standards for Treatment of Infectious Wastes,
below.
OSHA Regulations
In addition to the state medical waste environmental
regulations there are some Occupational Safety and Health Administration
(OSHA) rules that apply to medical/infectious waste. Ohio is one of
26 states covered entirely by the federal OSHA program. This program
is operated by the Occupational Safety and Health Administration. OSHA
rules (Occupational Exposure to Bloodborne Pathogens Standards) impact
various aspects of medical/infectious waste, including management of
sharps, requirements for containers that hold or store medical/infectious
waste, labeling of medical/infectious waste bags/containers, and employee
training. These requirements can be found in the VetCA section entitled OSHA Standards for Regulated Waste.
Statutes, Regulations
and Guidelines
OAC
Chapter 3745-27: Solid & Infectious Waste Regulations
Standards
for Generators of Infectious Waste
Requirements
for Infectious Waste Registration Certificate
Infectious
Waste Shipping Paper System
Standards
for Packaging Infections Wastes
Standards
for Treatment of Infectious Wastes
Contacts
The Division of Solid & Infectious Waste Management
(DSIWM) Central Office is comprised of several technical units. These
units provide technical expertise regarding various different regulatory
programs to DSIWM District Office field staff, the regulated community,
and the general public. Contact
the Division of Solid and Infectious Waste Management
An
infectious waste specialist in the Ohio EPA central office who can
be reached by telephone at 614-644-2621 or write to: Ohio EPA - DSIWM;
Infectious Waste Specialist; P.O. Box 1049; Columbus, OH 43216-1049.
More Information
Division of Solid and Infectious Waste Management Infectious Waste Guidance Documents
To subscribe to the Ohio
EPA Listserv for Infectious Waste rules, send an e-mail to majordomo@lists.epa.state.oh.us and
place the following in the message body: "subscribe iwrules".
|